How to prepare a GHG inventory: scope 1, scope 2 and scope 3 emissions explained
- August 19, 2026
- Posted by: PQS_Mitra_Main_Access
- Category: Environmental Social and Governance (ESG)


Companies are increasingly expected to measure and disclose their greenhouse gas emissions. Customers may request carbon data through supplier questionnaires, sustainability assessments, ESG disclosures, CDP reporting or science-based target programmes.
However, a greenhouse gas inventory is not simply a list of electricity bills and fuel purchases. It is a structured accounting system that identifies emission sources, defines reporting boundaries, applies appropriate calculation methods and presents results in a consistent and transparent manner.
A reliable GHG inventory enables an organisation to understand where emissions arise, establish a credible baseline, set reduction targets and monitor progress over time.
What Is a GHG Inventory?
A greenhouse gas inventory is a quantified statement of the greenhouse gas emissions and removals associated with an organisation during a defined reporting period.
The GHG Protocol Corporate Standard provides requirements and guidance for preparing corporate-level GHG inventories. ISO 14064-1:2018 similarly specifies principles and requirements for designing, developing, managing and reporting an organisation-level GHG inventory.
A complete inventory should clearly identify:
• The reporting organisation
• The reporting period
• Organisational and operational boundaries
• Included greenhouse gases
• Emission sources
• Activity data
• Emission factors
• Calculation methods
• Assumptions and exclusions
• Base year
• Quality-control arrangements
• Total emissions by category
The final result is generally reported in tonnes of carbon dioxide equivalent, written as tCO₂e.
Why Are Different Greenhouse Gases Reported as CO₂e?
Business activities can release multiple greenhouse gases, including:
• Carbon dioxide
• Methane
• Nitrous oxide
• Hydrofluorocarbons
• Perfluorocarbons
• Sulphur hexafluoride
• Nitrogen trifluoride
These gases do not have the same warming effect.
To make emissions comparable, the quantity of each gas is multiplied by its applicable global warming potential. The result is converted into carbon dioxide equivalent.
A basic calculation follows the structure:
GHG emissions = Activity data × Emission factor
Where required:
CO₂e = Quantity of greenhouse gas × Global warming potential
For example, diesel consumption may be multiplied by a fuel-specific emission factor to calculate kilograms of CO₂e. The result can then be converted into tonnes of CO₂e.
Step 1: Define the Purpose of the Inventory
Before collecting data, the organisation should establish why the inventory is being prepared.
Possible purposes include:
• Internal carbon management
• Customer disclosure
• ESG or sustainability reporting
• EcoVadis assessment
• CDP disclosure
• Science-based target development
• Regulatory preparation
• Independent verification
• Product or supply-chain decarbonisation
The intended use affects the required level of detail, evidence, reporting structure and assurance.
An internal screening inventory may use estimates for less significant sources. A customer submission or independently verified report may require stronger source documentation and more detailed calculation controls.
Step 2: Establish the Organisational Boundary
The organisational boundary determines which operations, legal entities, facilities and subsidiaries are included in the inventory.
Under recognised GHG accounting approaches, companies generally consolidate emissions using either an equity-share approach or a control approach.
Equity-share approach
The organisation accounts for emissions according to its share of equity in an operation.
Financial-control approach
The organisation accounts for emissions from operations over which it has the ability to direct financial and operating policies.
Operational-control approach
The organisation accounts for emissions from operations where it has authority to introduce and implement operating policies.
The selected approach should be applied consistently.
For example, a company may operate:
• A registered office
• Two manufacturing plants
• A leased warehouse
• A sales office
• A joint venture
• A company-owned vehicle fleet
The inventory must clearly state which of these operations are included and why.
An unclear organisational boundary can lead to missing emissions, double counting and inconsistency between reporting years.
Step 3: Define the Reporting Period and Base Year
The reporting period normally covers 12 consecutive months, such as:
• January to December
• April to March
• Another defined financial or operational year
The organisation should use a reporting period that aligns with the availability of operational and financial data.
A base year is the historical period against which future emissions performance is compared. It becomes the reference point for reduction targets.
The base year should:
• Represent normal business operations
• Have reasonably complete data
• Be clearly documented
• Be suitable for future comparison
• Be recalculated when significant structural changes occur
Acquisitions, divestments, outsourcing, insourcing or major changes in calculation methodology may require base-year recalculation to preserve comparability.
Step 4: Identify Scope 1 Emissions
Scope 1 covers direct GHG emissions from sources owned or controlled by the organisation.
Common Scope 1 sources include:
Stationary combustion
Fuel burned in equipment such as:
• Boilers
• Furnaces
• Thermic-fluid heaters
• Kilns
• Diesel generators
• Ovens
• Incinerators
Typical fuels include diesel, furnace oil, natural gas, LPG, coal, biomass and briquettes.
Mobile combustion
Fuel consumed by company-owned or company-controlled vehicles, including:
• Cars
• Trucks
• Forklifts
• Buses
• Material-handling equipment
Process emissions
Emissions arising from industrial or chemical processes rather than fuel combustion.
Examples may include:
• Chemical reactions
• Cement production
• Metal processing
• Refrigerant manufacturing
• Carbonate use
• Wastewater treatment
Fugitive emissions
Unintentional releases from equipment or systems, such as:
• Refrigerant leakage
• Air-conditioning gas losses
• Fire-suppression gases
• Natural-gas leakage
• Sulphur hexafluoride leakage
A frequent inventory weakness is the omission of refrigerants. Companies may record the number of air-conditioning units but fail to maintain data on gas refilling, leakage or equipment capacity.
Step 5: Identify Scope 2 Emissions
Scope 2 covers indirect emissions from purchased or acquired electricity, steam, heat and cooling consumed by the reporting organisation. The GHG Protocol Scope 2 Guidance standardises the accounting of these sources.
For most organisations, purchased electricity is the main Scope 2 source.
A basic electricity calculation may be expressed as:
Purchased electricity in kWh × Grid emission factor = Scope 2 emissions
Where applicable, Scope 2 emissions may need to be reported using two methods.
Location-based method
This method reflects the average emissions intensity of the electricity grid from which energy is consumed.
Market-based method
This method reflects emissions associated with contractual electricity instruments, such as eligible renewable-energy contracts, supplier-specific factors or recognised energy-attribute certificates.
The GHG Protocol’s current framework uses dual reporting where contractual instruments are available: one location-based result and one market-based result.
Organisations should avoid automatically treating solar power or renewable-energy purchases as zero emissions without checking ownership, contractual claims and applicable accounting requirements.
Step 6: Screen Scope 3 Emissions
Scope 3 includes indirect emissions occurring in the organisation’s value chain that are not included within Scope 1 or Scope 2.
The GHG Protocol Scope 3 Standard organises value-chain emissions into 15 upstream and downstream categories.
Upstream Scope 3 categories
1. Purchased goods and services
2. Capital goods
3. Fuel- and energy-related activities
4. Upstream transportation and distribution
5. Waste generated in operations
6. Business travel
7. Employee commuting
8. Upstream leased assets
Downstream Scope 3 categories
9. Downstream transportation and distribution
10. Processing of sold products
11. Use of sold products
12. End-of-life treatment of sold products
13. Downstream leased assets
14. Franchises
15. Investments
Not every category is relevant to every company.
A manufacturing company may have significant emissions from purchased raw materials, transportation, waste and product use. A ghg consulting organisation may have more material emissions from purchased services, business travel, employee commuting and leased offices.
The company should conduct a Scope 3 screening exercise to identify relevant and significant categories rather than excluding them without assessment.
Step 7: Select the Appropriate Calculation Method
Different emission sources require different calculation methods.
Activity-based method
This method uses physical data such as:
• Litres of diesel
• Kilograms of LPG
• Kilowatt-hours of electricity
• Tonnes of material purchased
• Tonne-kilometres of freight
• Passenger-kilometres of travel
• Kilograms of waste treated
Activity-based calculations are generally more useful for identifying operational reduction opportunities.
Spend-based method
This method multiplies expenditure by an economic emission factor.
It may be useful during initial Scope 3 screening where physical data is unavailable. However, it may be affected by inflation, exchange rates, product prices and broad sector averages.
Supplier-specific method
This method uses emissions data provided directly by suppliers.
Supplier-specific data can improve accuracy where:
• The calculation boundary is clear
• The data relates to the purchased product or service
• The supplier’s methodology is documented
• Double counting is avoided
• The information covers the correct reporting period
Hybrid method
A hybrid approach combines supplier-specific, activity-based and spend-based data.
The GHG Protocol provides category-specific calculation guidance for all 15 Scope 3 categories and explains how organisations can choose suitable methods.
Step 8: Use Appropriate Emission Factors
An emission factor represents the quantity of GHG emissions associated with a unit of activity.
Examples include:
• kgCO₂e per litre of diesel
• kgCO₂e per kWh of electricity
• kgCO₂e per tonne-kilometre
• kgCO₂e per kilogram of material
• kgCO₂e per hotel night
• kgCO₂e per passenger-kilometre
Emission factors should be selected using a documented hierarchy.
Factors should be:
• Relevant to the country or region
• Applicable to the activity and technology
• Current for the reporting period
• Based on a credible source
• Consistent with the unit of activity data
• Transparent about included gases and boundaries
A common error is mixing units—for example, applying a kilogram-based factor to data recorded in tonnes without conversion.
Step 9: Apply Quality Controls
A technically correct formula can still produce an unreliable inventory when the underlying data is incomplete.
The organisation should check:
• Whether all reporting locations are included
• Whether fuel units are correct
• Whether gross and net calorific values are mixed
• Whether electricity data includes common-area consumption
• Whether renewable electricity claims are supported
• Whether freight distance and load data are reasonable
• Whether purchased materials are double counted
• Whether waste quantities reconcile with disposal records
• Whether refrigerant refills reflect leakage or inventory additions
• Whether emission factors match the reporting year
• Whether formulas and unit conversions are locked and reviewed
Data should be traceable to evidence such as invoices, meter readings, purchase records, travel reports, waste manifests, logistics records and supplier information.
Step 10: Report Results Transparently
A GHG inventory report should present:
• Organisational profile
• Reporting purpose
• Reporting period
• Organisational boundary
• Operational boundary
• Calculation methodology
• Emission-factor sources
• Scope 1 emissions
• Scope 2 emissions
• Relevant Scope 3 emissions
• Biogenic emissions, where applicable
• Exclusions
• Assumptions
• Data limitations
• Base-year information
• Recalculation policy
• Uncertainty or data-quality observations
• Reduction initiatives
• Management responsibility
Transparency is especially important when estimated data is used.
An estimate is not automatically unacceptable. The company should explain why it was necessary, how it was calculated and whether it is material to the total inventory.
Common GHG Inventory Mistakes
Companies frequently encounter the following issues:
• Reporting only electricity and diesel
• Excluding Scope 3 without screening
• Missing refrigerant emissions
• Using outdated or inappropriate emission factors
• Combining multiple years of data
• Mixing litres, kilograms and tonnes
• Applying spend-based factors to physical quantities
• Reporting renewable electricity without contractual evidence
• Including carbon offsets as emission reductions
• Changing boundaries without recalculating the base year
• Reporting results without maintaining source records
• Setting targets before establishing a stable baseline
These weaknesses can make year-on-year comparison unreliable.
How PQSmitra Supports GHG Accounting
PQSmitra supports organisations with:
• GHG inventory boundary definition
• Scope 1, Scope 2 and Scope 3 screening
• Data-requirement templates
• Activity-data compilation
• Emission-factor identification
• Carbon-footprint calculations
• Base-year development
• GHG inventory reporting
• Reduction-target development
• Carbon-reduction action plans
• Employee and process-owner training
• Pre-verification technical review
The approach is designed to convert operational, procurement, logistics and financial data into a traceable and decision-useful GHG inventory.
Conclusion
A credible GHG inventory begins with clearly defined boundaries and reliable activity data. It requires more than applying emission factors to utility bills.
Companies must identify direct emissions, account for purchased energy, screen value-chain emissions and maintain transparent calculation records.
When the inventory is prepared systematically, it becomes more than a disclosure requirement. It provides management with a technical basis for identifying emission hotspots, prioritising investments, engaging suppliers and measuring real progress toward carbon-reduction targets. For expert support in developing a reliable and verifiable greenhouse gas inventory, explore PQSmitra’s GHG Accounting and Carbon Footprint Services.
Leave a Reply Cancel reply
Kindly submit a business inquiry online and we will get back to you!
OR
Call us on +91-9820204373